«MEDICAL POLICY SUBJECT: PNEUMATIC COMPRESSION EFFECTIVE DATE: 09/26/02 DEVICES/LYMPHEDEMA PUMPS REVISED DATE: 10/23/03, 09/23/04, 10/27/05, 12/07/06, ...»

-- [ Page 1 ] --

MEDICAL POLICY

SUBJECT: PNEUMATIC COMPRESSION EFFECTIVE DATE: 09/26/02

DEVICES/LYMPHEDEMA PUMPS REVISED DATE: 10/23/03, 09/23/04, 10/27/05, 12/07/06,

02/28/08, 04/23/09, 08/27/09, 08/26/10,

02/27/12, 02/28/13, 02/27/14, 02/26/15,

POLICY NUMBER: 1.01.17 02/25/16

CATEGORY: Equipment/ Supplies PAGE: 1 OF: 5

• If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply.

• If a commercial product, including an Essential Plan product, covers a specific service, medical policy criteria apply to the benefit.

• If a Medicare product covers a specific service, and there is no national or local Medicare coverage decision for the service, medical policy criteria apply to the benefit.

POLICY STATEMENT:

I. Based upon our criteria, both the non-segmental compression devices (HCPC Code E0650) and segmental compression devices with or without calibrated gradient pressure (HCPC Codes E0651, E0652) are medically appropriate for use in the home in the treatment of intractable lymphedema of the extremities.

II. Based upon our criteria, segmental compression devices with calibrated gradient pressure which include both a twophase or multi-phase lymph preparation phase as well as drainage phase therapy devices (e.g., Flexitouch™ Device, Lymphapress Optimal) (E0652) are considered medically appropriate when the patient has documented large volume disease or large areas of fibrosis caused by radiation therapy or repeated infections; AND A. a non-segment or segmental compression device has been shown to be ineffective; and B. the patient has undergone a supervised training program and is able to show proficiency in using the device; and C. documented improvement after a one month trial period using the device.

III. Based on our criteria, pneumatic compression devices (HCPC codes E0650, E0651, E0652, E0675, E0676; (e.g., ACTitouch® device) have not been medically proven to be effective and are considered investigational for the

following indications:

A. venous stasis ulcers; or B. peripheral artery disease (e.g., intermittent claudication, ischemia, arterial insufficiency); or C. lower extremity and truncal edema due to obesity.

Refer to Corporate Medical Policy 1.01.51 Limb Pneumatic Compression Devices for Venous Thromboembolism Prophylaxis.

Refer to Corporate Medical Policy #10.01.01 regarding Breast Reconstruction Surgery.

Refer to Corporate Medical Policy #11.01.03 regarding Experimental and Investigational Services.

POLICY GUIDELINES:

I. Medical documentation of all the following is required for considerationof a pneumatic compression device/

lymphedema pump:

A. The lymphedema is intractable (lymphedema which has been difficult to manage and nonresponsive to decongestive treatment). Documentation should include etiology, symptoms and objective findings, measurements establishing the severity of the condition, and the extent to which the lymphedema impairs function of the extremity causing pain and gross distention.

B. Previous less intensive treatments have been tried and found inadequate (e.g., leg/arm elevation, custom fabricated gradient pressure stockings or sleeves, and exercise); and C. Appropriate physician oversight (e.g., instruction in the operation of the machine, amount of pressure to be used, the frequency and duration of use, and ongoing monitoring of use and response to treatment).

Proprietary Information of Excellus Health Plan, Inc.

A nonprofit independent licensee of the BlueCross BlueShield Association SUBJECT: PNEUMATIC COMPRESSION EFFECTIVE DATE: 09/26/02 DEVICES/LYMPHEDEMA PUMPS REVISED DATE: 10/23/03, 09/23/04, 10/27/05, 12/07/06, 02/28/08, 04/23/09, 08/27/09, 08/26/10, 02/27/12, 02/28/13, 02/27/14, 02/26/15, POLICY NUMBER: 1.01.17 02/25/16 CATEGORY: Equipment/ Supplies PAGE: 2 OF: 5

II. Home use will be dependent upon the clinical response to treatment, including:

A. Change from pre-treatment to post-treatment measurements;

B. Ability to tolerate the treatment session parameters; and C. Ability of the patient (or caregiver) to apply the device for continued use in the home.

III. Durable Medical Equipment rider/coverage is required. (Except for a postmastectomy diagnosis in accordance with the Women’s Health and Cancer Rights Act).

IV. The Federal Employee Health Benefit Program (FEHBP/FEP) requires that procedures, devices or laboratory tests approved by the U.S. Food and Drug Administration (FDA) may not be considered investigational and thus these procedures, devices or laboratory tests may be assessed only on the basis of their medical necessity.

DESCRIPTION:

Lymphedema is the abnormal accumulation of lymph fluid in the subcutaneous tissues of an affected body part due to an

obstruction of the lymphatic flow. Lymphedema is a relatively uncommon condition which may be due to:

I. Surgical removal of lymph nodes, II. Post-radiation fibrosis, III. Scarring of lymphatic channels, IV. Onset of puberty (Milroy’s Disease), V. Congenital anomalies, or VI. Spread of malignant tumors to regional lymph nodes.





Lymphedema is considered to be incurable. Treatment focuses on decreasing the excess volume of the limb as much as possible and to maintain the limb at its smallest size.

Pneumatic compression devices/lymphedema pumps are devices which were developed to aid in the mobilization of lymph fluid from the extremity and to avoid the adverse consequences of uncontrolled lymphedema. These devices are often classified into three types: single compartment pumps; 2) multi-chamber devices with each chamber sequentially inflated but with fixed pressure in each; and 3) multi-chamber devices with sequential inflation and with manually calibrated pressure in each chamber.

Non-segmental compression pumps are the simplest type of pump and consist of a one boot or sleeve chamber that inflates and deflates during a single phase. Examples of these types pumps include the KCI Extremity pump 7000 and Huntleigh Flowpress.

Segmental compression pumps consist of three chambers which inflate sequentially with a fixed pressure during a single phase. Examples of these types pumps include the Flowtron Hydroven FPR pump, KCI Extremity pump 7500, Lympha Press, Petite Basic ™ 701A, and BioCompression Pump Model 2004.

Segmental compression pumps with calibrated, gradient pressure direct the lymph fluid from the extremity towards the body by decreasing the pressure in the chambers from the farthest part of the body to the closest in a single phase. The pressure can be changed or tailored in each individual chamber sleeve. These pumps can be equipped with two-phases, a preparatory phase, which acts similarly to manual decongestive therapy by using a light, variable pressure to prepare the trunk and extremity prior to draining the fluid from the affected extremity and a compression phase. The Flexitouch™ (Tactile Systems Technology, Inc) system is an example of a segmental compression pump with calibrated, gradient pressure and two-phases. This device received 510(k) approval from the FDA as a class II device under the name Biotouch™ Massage Therapy System. Another device by Tactile Systems Technology, Inc, is the ACTitouch® system which combines intermittent and sustained compression therapy in one easy-to-wear device for treatment of venous ulcers. The ACTitouch® system is designed to accommodate a wide range of leg shapes and sizes and can be worn under regular clothing and with most shoes. In sustained compression mode, the compact, lightweight device gives patients the freedom to stay active while experiencing the benefits of dual-compression therapy. The device inflates to preset pressures to ensure consistent, predictable compression, regardless of variations in sleeve application. To deliver Proprietary Information of Excellus Health Plan, Inc.

SUBJECT: PNEUMATIC COMPRESSION EFFECTIVE DATE: 09/26/02 DEVICES/LYMPHEDEMA PUMPS REVISED DATE: 10/23/03, 09/23/04, 10/27/05, 12/07/06, 02/28/08, 04/23/09, 08/27/09, 08/26/10, 02/27/12, 02/28/13, 02/27/14, 02/26/15, POLICY NUMBER: 1.01.17 02/25/16 CATEGORY: Equipment/ Supplies PAGE: 3 OF: 5 effective compression throughout the day, the system monitors pressures every 30 minutes, adjusting the inflation in response to anatomic changes. The Lymphapress Optimal also has the capability to deliver Pretherapy™ based on the principles of manual lymph drainage. The Lympha Press Optimal Compression Therapy Device received FDA approval in 2008.

Home-based devices that deliver intermittent pneumatic compression have also been proposed to treat venous leg ulcers and intermittent claudication. These devices apply rapid and timed compression to the foot and calf which is proposed to move blood through deep veins at a high pulsatile rate and increase arterial blood flow.

The Women’s Health and Cancer Rights Act of 1998 mandated coverage for physical complications, including lymphedemas, of mastectomies for all contracts that provide medical and surgical benefits.

RATIONALE:

There is insufficient evidence in the peer-reviewed literature that segmental compression pumps with calibrated, gradient pressure two-phase lymph preparation and drainage therapy devices provide outcomes equal or superior to standard pneumatic compression devices. One randomized, single-center, crossover study involving 10 patients that compared the efficacy of the Flexitouch™ device to massage for treatment of lymphedema of the arm was found in the literature. The study was limited by small sample size, short duration of treatment and no comparison to standard pneumatic lymphedema pumps or complex lymphedema therapy. Another similar study compared pressure delivered to parts of the arm between a segmental compression pump and the Flexitouch device. Differences in delivered pressures between the two devices was observed, but no conclusion regarding the optimal pressure needed was made.

There is insufficient evidence in the peer-reviewed literature that edema in the lower extremities is a result of obstruction in the lymphatic system caused by obesity. However preliminary studies have shown that obese individuals are more likely to develop edema in the lower extremities. Additional studies are needed to determine the functional role of lymphatic vasculature in the obese patient.

There is insufficient evidence in the peer-reviewed literature that intermittent pneumatic compression(IPC) improves outcomes in patients with venous stasis ulcers and arterial insufficiency. Preliminary studies have proposed IPC improves exercise tolerance in a model of peripheral arterial insufficiency in part by enhancing blood flow to collateraldependent tissues but further research is needed to validate use for these indications.

Number Description

CODES:

Eligibility for reimbursement is based upon the benefits set forth in the member’s subscriber contract.

CODES MAY NOT BE COVERED UNDER ALL CIRCUMSTANCES. PLEASE READ THE POLICY AND

GUIDELINES STATEMENTS CAREFULLY.

Codes may not be all inclusive as the AMA and CMS code updates may occur more frequently than policy updates.

No code(s)

CPT:

Copyright © 2016 American Medical Association, Chicago, IL E0650 Pneumatic compressor, nonsegmental home model

HCPCS:

E0651 Pneumatic compressor, segmental home model without calibrated gradient pressure E0652 Pneumatic compressor, segmental home model with calibrated gradient pressure E0655 Nonsegmental pneumatic appliance for use with pneumatic compressor, half arm E0656 Segmental pneumatic appliance for use with pneumatic compressor, trunk E0657 Segmental pneumatic appliance for use with pneumatic compressor, chest E0660 Nonsegmental pneumatic appliance for use with pneumatic compressor, full leg Proprietary Information of Excellus Health Plan, Inc.

SUBJECT: PNEUMATIC COMPRESSION EFFECTIVE DATE: 09/26/02 DEVICES/LYMPHEDEMA PUMPS REVISED DATE: 10/23/03, 09/23/04, 10/27/05, 12/07/06, 02/28/08, 04/23/09, 08/27/09, 08/26/10, 02/27/12, 02/28/13, 02/27/14, 02/26/15, POLICY NUMBER: 1.01.17 02/25/16 CATEGORY: Equipment/ Supplies PAGE: 4 OF: 5 E0665 full arm E0666 half leg E0667 Segmental pneumatic appliance for use with pneumatic compressor, full leg E0668 full arm E0669 half leg E0671 Segmental gradient pressure pneumatic appliance, full leg E0672 full arm E0673 half leg E0675 Pneumatic compression device high pressure, rapid inflation./deflation cycle, for arterial insufficiency (unilateral or bilateral system) E0676 Intermittent limb compression device (includes all accessories), not otherwise specified 457.0 Postmastectomy lymphedema syndrome

ICD9:

457.1 Other lymphedema 757.0 Hereditary edema of the legs I89.0 Lymphedema, not elsewhere classified

ICD10:

I97.2 Postmastectomy lymphedema syndrome Q82.0 Hereditary lymphedema

REFERENCES:

BlueCross BlueShield Association. Pneumatic Compression Pumps for Treatment of Lymphedema and Venous Ulcers.

Medical Policy Reference Manual Policy #1.01.18. 2015 Sep 10.

*BlueCross BlueShield Association Technology Assessment Program (TEC). Special report: comparative efficacy of different types of pneumatic compression pumps for the treatment of lymphedema. 1998 Apr;13(2).

Feist WR, et al. Problems with measuring compression device performance in preventing deep vein thrombosis. Throm Res 2011 Sep;128(3):207-9.

Finane A, et al. Review of the evidence of lymphedema treatment effect. Am J Phys Med Rehabil 2015 Jun;94(6):483Geerts WH, et al. Prevention of venous thromboembolism: the seventh ACCP Conference on antithrombotic and thrombolytic therapy. Chest 2004;126(Supp1 3):338S-400S.

*Haslett ML, et al. Evaluating the effectiveness of a compression sleeve in managing secondary lymphedema. J Wound Care 2002 Nov;11(10):401-4.

*Hassell a, et al. A retrospective study of the effects of the lymphapress pump on lymphedema in a pediatric population.

Lymphol 2001 Dec;34(4):156-65.



Pages:   || 2 |


Similar works:

«Health and Safety Executive Work-related respiratory disease in Great Britain 2014 An overview of the current burden of disease in Great Britain Contents Summary 2 Introduction 3 Work-related respiratory diseases 3 Disease latency 3 Overall scale of work-related respiratory disease 4 Mortality 4 Table 1: Current annual mortality from respiratory diseases in Great Britain 4 Prevalence of self-reported respiratory disease 5 Causes of self-reported respiratory disease 5 New cases occurring each...»

«ВОСПОМИНАНИЯ КОЛЛЕГ ОБ АКАДЕМИКЕ АМН СССР ВИКТОРЕ МИХАЙЛОВИЧЕ ЖДАНОВЕ (раздел подготовили: чл.-корр. РАМН Л.В. Урываев и академик РАН Ф.И. Ершов) MEMOIRS OF COLLEAGUE ABOUT ACADEMICIAN OF SOVIET UNION ACADEMY OF MEDICAL SCIENCES VICTOR MIKHAILOVICH ZHDANOV (section prepared by Uryvaev L.V., Ershov F.I.) Н.Ф. Измеров, д.м.н., профессор, академик РАН,...»

«Effects of Health Care Payment Models on Physician Practice in the United States Mark W. Friedberg, Peggy G. Chen, Chapin White, Olivia Jung, Laura Raaen, Samuel Hirshman, Emily Hoch, Clare Stevens, Paul B. Ginsburg, Lawrence P. Casalino, Michael Tutty, Carol Vargo, Lisa Lipinski C O R P O R AT I O N For more information on this publication, visit www.rand.org/t/rr869 Library of Congress Control Number: 2015935308 ISBN: 978-0-8330-8894-9 Published by the RAND Corporation, Santa Monica, Calif....»

«Puffer Cries Shark Rainbow Fish It receive as allocated on medicine powers or advertising partners are more giveaway to return of we are if a capacity them include being. Rising this choice which continued I was means payments with your aid to cut the $50 product. More, FIXED but 1.this will understand the most procurement application within a licensee possible to your new time to need and needed forecast with stress. In more, your funding marketplace call actions will maybe understand in sure...»

«‘Best Practice’ Guidelines for Managing the Disclosure of De-Identified Health Information Prepared by the: Health System Use Technical Advisory Committee Data De-Identification Working Group October 2010 For more information on this document, please contact: Canadian Institute for Health Information 495 Richmond Road, Suite 600 Ottawa, ON K2A 4H6 Phone: (613) 241-7860 (Communications) Fax #: (613) 241-8120 Email: communications@cihi.ca www.cihi.ca ii Table of Contents 1 EXECUTIVE SUMMARY 2...»

«Intelligence Predicts Health and Longevity, but Why? Linda S. Gottfredson1 and Ian J. Deary School of Education, University of Delaware, Newark, Delaware (L.S.G.), and Department of Psychology, University of Edinburgh, Edinburgh, Scotland, United Kingdom (I.J.D.) Abstract Large epidemiological studies of almost an entire population in Scotland have found that intelligence (as measured by an IQ-type test) in childhood predicts substantial differences in adult morbidity and mortality, including...»

«ANNUAL REPORT July 1, 1989 June 30, 1990 DEPARTMENT OF PHYSIOLOGY UNIVERSITY OF KANSAS MEDICAL CENTER COLLEGE OF HEALTH SCIENCES AND HOSPITAL DEPARTMENTROSTER a. AcademicStaff Gilbert S. Greenwald, Ph.D., Distinguished Professor and Chairman Paul D. Cheney, Ph.D., Professor (Director of Ralph L. Smith Center for Mental Retardation) Richard L. Clancy, Ph.D., Professor Sudhansu K. Dey, Ph.D., Professor (Joint appt. Ob-Gyn) Hugo L. Fernandez, Ph.D., Professor (Director,Neurosciences Research Lab.,...»

«Statistical Bulletin Deaths Registered in England and Wales, 2012 Coverage: England and Wales Date: 10 July 2013 Geographical Areas: Local Authority and County, Region Theme: Population Theme: Health and Social Care Deaths Registered in England and Wales, 2012 • There were 499,331 deaths registered in England and Wales in 2012, compared with 484,367 in 2011 (a rise of 3.1%).• The infant mortality rate decreased in 2012 to 4.2 deaths per thousand live births compared with 4.4 in 2011. •...»

«OXFORD DOCTORAL COURSE IN CLINICAL PSYCHOLOGY SERVCE RELATED PROJECT CANDIDATE NUMBER: 1519/09 PAEDIATRIC PSYCHOLOGISTS’ RATINGS OF OUTCOME MEASURES AND OUTCOME MEASUREMENT Date of submission: 21.05.10 Specialty: Child and Adolescent Mental Health Year of intake: 2009 Accurate word count: 4,327 ABSTRACT No guidelines for the use of outcome measures exist for paediatric psychology services. Paediatric psychologists’ use of outcome measures (OMs) and their ratings of the usefulness of...»

«Gesundheitsförderung, Lebensqualität und Stressbewältigung im Medizinstudium Inaugural-Dissertation zur Erlangung des Grades eines Doktors der Medizin des Fachbereiches Medizin der Justus-Liebig-Universität Gießen vorgelegt von Linda Krug, geb. Schmidt aus Gießen Gießen, 2009 Aus dem Medizinischen Zentrum für Psychosomatische Medizin Klinik für Psychosomatik und Psychotherapie der Universitätsklinikum Gießen und Marburg GmbH, Standort Gießen. Direktor: Prof. Dr. Kruse Gutachter:...»

«U.S. Agency for International Development BASICS Bureau for Global Health 4245 N. Fairfax Dr., Suite 850 Office of Health, Infectious Arlington, VA 22203 Diseases and Nutrition USA Ronald Reagan Building Tel: (703) 312-6800 1300 Pennsylvania Ave., NW Fax: (703) 312-6900 Washington, D.C. 20523 Email: basics@basics.org USA www.basics.org Tel: (202) 712-0000 Email: globalhealth@phnip.com www.usaid.gov/our_work/global_health Cette publication a été réalisée grâce au soutien du Directorat de la...»

«LeisureCare Note: For Trip Cancellation and Trip Interruption claims, reimbursement will be made in the form of a check, issued by the Program Administrator. Important This program is valid only if the appropriate plan cost has been received by World Travel Holdings. Please keep this document as your record of coverage. Transamerica Casualty Insurance Company Policy Number: MZ0911122H0004A Description of Coverage Schedule: World Travel Holdings Maximum Benefit Amount Part A. Travel Arrangement...»





 
<<  HOME   |    CONTACTS
2016 www.book.xlibx.info - Free e-library - Books, abstracts, thesis

Materials of this site are available for review, all rights belong to their respective owners.
If you do not agree with the fact that your material is placed on this site, please, email us, we will within 1-2 business days delete him.